perma PRO
- 20 -
Indication
of the
display
Error
Possible cause
Remedial measures
E I
Lubricator has been switched off
Excess motor current of the
lubricator motor due to a blocked
outlet
Battery set is empty
Clear the blockage and ack-
nowledge the fault by pushing
and holding down the ON/
OFF/SELECT button
Insert a new battery set and
use a full PRO LC unit
E4
Lubricator has been switched off
Drive mechanism is defective
Exchange the drive unit
LC
System does not detect
the PRO LC unit
No PRO LC unit installed
Install an PRO LC unit
L
No power supplied to the system
from the battery
No battery inserted or battery set
empty
Insert a new battery set and
use a full PRO LC unit
In addition to the above, the following malfunctions can occur when a perma MP-6 distributor is connected to the
lubrication system:
E0
Lubrication system has been
switched off
Excess motor current of the perma
MP-6
Replace perma MP-6
distributor
F I
to
f6
Error at the displayed lubrication
point
Excess motor current of the
lubricator motor caused by a
blocking of the displayed outlet
Clear the blockage and ack-
nowledge the fault by pushing
and holding down the ON/
OFF/SELECT button
E2
Lubrication system has been
switched off
Outlets of distributor not correctly
recognized
Replace distributor
E3
Lubrication system has been
switched off
Timeout while activating distributor
Connection cable damaged
Replace distributor
Replace connection cable
E5
Outlet configuration missing
Outlets were not activated
Activate desired outlets
chart 7
8.
Trouble Shooting
8.1
Error Messages on the Display
Possible errors of the lubrication system and the application are detected by the electronic control system and are
indicated on the display. If an error is displayed, the system is switched OFF until the cause of the error has been
eliminated and the error message has been acknowledged.
Error messages are acknowledged and reset by pushing the ON/OFF/SELECT button.
8.2
Trouble Shooting Guide
If there are malfunctions during the operation of the lubrication system, please check for possible causes using
the following chart (refer to chart 7).
Every time that an error message is displayed, the red LED is also blinking.
Содержание Distributor PRO MP-6
Страница 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Страница 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Страница 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Страница 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...