BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Potentiometer input module ...............................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

GENERAL PRECAUTIONS

• Before you remove the terminal block or mount it, turn off  

input signals for safety.

 

HOT SWAPPABLE MODULES

• It is possible to replace a module with the power supplied 

provided that the module is replaced with one with the 
same model number and installed in the same base slot.

• Turn off input signals before replacing the module for 

safety.  Note that replacing multiple modules at once may 
greatly change line voltage levels.  We highly recommend 
to replace them one by one.

 

UNUSED CHANNEL

• Set unused channels to “CH disabled” with PC Configura-

tor software (model: R30CFG).  Otherwise, unused chan-
nels left open are to be indefinite status.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 10 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• Be sure to attach the terminal cover for safety.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

Содержание R30MS4

Страница 1: ...terminal block or mount it turn off input signals for safety HOT SWAPPABLE MODULES It is possible to replace a module with the power supplied provided that the module is replaced with one with the same model number and installed in the same base slot Turn off input signals before replacing the module for safety Note that replacing multiple modules at once may greatly change line voltage levels We ...

Страница 2: ...with input value error becomes less than the lower limit or exceeds the upper limit of usable range Blinks in 400 msec cycles with input circuit error AD converter response failure ON with internal bus error TERMINAL ASSIGNMENTS 11 NC 12 L1 13 NC 14 L2 15 NC 16 NC 17 L3 18 NC 19 L4 20 NC 1 H1 2 S1 3 H2 4 S2 5 NC 6 H3 7 S3 8 H4 9 S4 10 NC NO ID FUNCTION NO ID FUNCTION 1 H1 Potentiometer 1 H 11 NC N...

Страница 3: ... slot is vacant blank data is sent or received to from the PLC etc PWR COM I O1 I O n HOW TO MOUNT THE MODULE 1 Engage the positioning guide of the module with the In stallation Base 2 Pivot the module on the positioning guide and press it down until the lock tab clicks into place Positioning Guide 3 Tighten the base fixing screw using a screwdriver stem length 70 mm 2 76 or more torque 0 5 N m Ba...

Страница 4: ...ERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 110 4 33 25 98 98 3 86 20 M3 SCREW 6 24 CONNECTION DIAGRAM 1 2 12 3 4 14 INTERNAL POWER BUS CONNECTOR INTERNAL BUS INPUT 1 INPUT 2 INPUT 3 INPUT 4 6 7 17 8 9 19 INPUT CONNECTION EXAMPLE H1 S1 H2 S2 L1 L2 H3 S3 H4 S4 L3 L4 min Sn Ln Hn 2 1 3 Potentiometer max ...

Страница 5: ...ia 12 47 max 6 max 24 3 12 max HOW TO REMOVE SEPARABLE SCREW TERMINAL The terminal block is separable in two pieces Evenly loos en two screws on top and bottom of the terminal block to separate PC CONFIGURATOR The following parameter items can be set with using PC Configurator Software model R30CFG Refer to the users manual for the R30CFG for detailed op eration of the software program CHANNEL IND...

Отзывы: