R30MS4

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-9004  Rev.2  P. 2 / 5

COMPONENT IDENTIFICATION

RUN

ERR

RUN LED

Input Terminal Block

ERR LED

 FRONT VIEW

 BOTTOM VIEW

 SIDE VIEW

Lock Tab

Base Fixing Screw

Specifications

Positioning Guide

Terminal Cover

Terminal Fixing Screw

1
2

3
4

5
6

7
8

9

10

11

12

13

14
15

16

17

18

19

20

 

STATUS INDICATOR LED

ID

COLOR

FUNCTION

RUN

Green

ON while network module operates normally
OFF in network module error

ERR

Red

OFF when input circuit and internal bus operate normally
Blinks in 1 sec. cycles with input value error (becomes less than the lower limit or exceeds the upper limit 
of usable range).
Blinks in 400 msec. cycles with input circuit error (AD converter response failure). 
ON with internal bus error

 

TERMINAL ASSIGNMENTS

11

NC

12

L1

13

NC

14

L2

15

NC

16

NC

17

L3

18

NC

19

L4

20

NC

1

H1

2

S1

3

H2

4

S2

5

NC

6

H3

7

S3

8

H4

9

S4

10

NC

NO.

ID

FUNCTION

NO.

ID

FUNCTION

1

H1

Potentiometer 1-H

11

NC

No connection

2

S1

Potentiometer 1-S

12

L1

Potentiometer 1-L

3

H2

Potentiometer 2-H

13

NC

No connection

4

S2

Potentiometer 2-S

14

L2

Potentiometer 2-L

5

NC

No connection

15

NC

No connection

6

H3

Potentiometer 3-H

16

NC

No connection

7

S3

Potentiometer 3-S

17

L3

Potentiometer 3-L

8

H4

Potentiometer 4-H

18

NC

No connection

9

S4

Potentiometer 4-S

19

L4

Potentiometer 4-L

10

NC

No connection

20

NC

No connection

Содержание R30MS4

Страница 1: ...terminal block or mount it turn off input signals for safety HOT SWAPPABLE MODULES It is possible to replace a module with the power supplied provided that the module is replaced with one with the same model number and installed in the same base slot Turn off input signals before replacing the module for safety Note that replacing multiple modules at once may greatly change line voltage levels We ...

Страница 2: ...with input value error becomes less than the lower limit or exceeds the upper limit of usable range Blinks in 400 msec cycles with input circuit error AD converter response failure ON with internal bus error TERMINAL ASSIGNMENTS 11 NC 12 L1 13 NC 14 L2 15 NC 16 NC 17 L3 18 NC 19 L4 20 NC 1 H1 2 S1 3 H2 4 S2 5 NC 6 H3 7 S3 8 H4 9 S4 10 NC NO ID FUNCTION NO ID FUNCTION 1 H1 Potentiometer 1 H 11 NC N...

Страница 3: ... slot is vacant blank data is sent or received to from the PLC etc PWR COM I O1 I O n HOW TO MOUNT THE MODULE 1 Engage the positioning guide of the module with the In stallation Base 2 Pivot the module on the positioning guide and press it down until the lock tab clicks into place Positioning Guide 3 Tighten the base fixing screw using a screwdriver stem length 70 mm 2 76 or more torque 0 5 N m Ba...

Страница 4: ...ERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 110 4 33 25 98 98 3 86 20 M3 SCREW 6 24 CONNECTION DIAGRAM 1 2 12 3 4 14 INTERNAL POWER BUS CONNECTOR INTERNAL BUS INPUT 1 INPUT 2 INPUT 3 INPUT 4 6 7 17 8 9 19 INPUT CONNECTION EXAMPLE H1 S1 H2 S2 L1 L2 H3 S3 H4 S4 L3 L4 min Sn Ln Hn 2 1 3 Potentiometer max ...

Страница 5: ...ia 12 47 max 6 max 24 3 12 max HOW TO REMOVE SEPARABLE SCREW TERMINAL The terminal block is separable in two pieces Evenly loos en two screws on top and bottom of the terminal block to separate PC CONFIGURATOR The following parameter items can be set with using PC Configurator Software model R30CFG Refer to the users manual for the R30CFG for detailed op eration of the software program CHANNEL IND...

Отзывы: