7
Introduction
RCS Climbing Device and Hydraulics
Assembly Instructions
Climbing Device RCS 50
Stroke length
effective 500 mm (maximum 575 mm)
Lifting power
maximum 50 kN (11.2 kip)
Operating pressure 190 bar (19 MPa)
Hydraulic Pump RCS 4 x 190 bar, 380 – 460 V
Power supply
400 V/50 Hz (3-phase) flow rate 6 l/min
Power supply
460 V/60 Hz (3-phase) flow rate 7 l/min
Sound emissions 64 dB (A) at a distance of 1.0 m
Information only – for use only in Canada:
Hydraulic Pump RCS 4 x 190 bar, 460 V CSA
Power supply
460 V/60 Hz (3-phase) flow rate 7 l/min
Cleaning and Maintenance Instructions
The Climbing Device RCS 50 has been
designed for long-term use on con-
struction sites.
In order to ensure cost-effective, techni-
cal and safe use over a long period, it is
important to take a value- preserving
approach.
Use in a way not intended or deviating
from the intended use according to the
Assembly Instructions represents a mis-
application with a potential safety risk.
Changes to PERI components are not
permitted.
Only PERI original parts may be used.
The use of other products and spare
parts represents a misapplication with
associated safety risks.
Instructions on Use
Repairs which require welding or defor-
mation of components must be carried
out by PERI.
Use PERI original components as spare
parts.
Operations with damaged or incomplete
lifting equipment are not permissible.
The system described in these Assembly
Instructions may contain patent-protect-
ed components.