24
RCS Climbing Device and Hydraulics
Assembly Instructions
Part C Maintenance
C3 Maintenance and Repairs
C3.1 Overview
Damage and any resulting downtime can
be avoided by carrying out scheduled
maintenance work.
PERI recommends shortened
maintenance intervals:
– for equipment showing signs of heavy
wear.
– with high thermal and mechanical loads.
– when subject to heavy soiling.
Maintenance and repairs
Recommended maintenance
intervals
Clean machine housing and cylinder.
Lubricate moving parts on the cylinder.
daily
Clean oil filter and replace if necessary,
see C3.5.
Replace hydraulic oil, see C3.4.
before use on next jobsite,
minimum 1x yearly
Replace hoses.
if damaged, before use on next
jobsite, minimum 1x yearly
Replace sealings.
with oil leakage
Check fluid level in the oil tank,
see C3.2.
Check oil temperature and oil level,
see C3.3.
Check whether there are signs of leakage.
Check working and control pressures.
Check whether any noises or vibrations are present.
daily to weekly
Check:
Equipment mountings
Pipe and hose lines (connections, chafe marks, kinks)
Protective covers, display devices
Ventilation filter in the filling piece
weekly to monthly
Check:
Machine housing (dirt, damage)
Efficiency control
monthly to quarterly
Check the complete hydraulic pump
(deposit formation, rust formation).
yearly