52
5
5.1
5.4
5
9.1
5.1
5.4
RCS Climbing Device and Hydraulics
Assembly Instructions
Part D Operations
D5 Remedial Measures for Malfunctions
D5.5 Releasing the climbing pawl by
hand
In the event of a broken leg spring in
the climbing shoe (5), manually release
the climbing pawl (5.1) with the help of
the pawl lock (5.4).
This procedure is required in order
to replace the climbing shoe.
After completing the climbing proce-
dure, replace the climbing shoe or
have repair work carried out by PERI!
Risk of crushing!
Do not touch if the load is moving!
Procedure:
1. Completely extend the pistons of all
hydraulic cylinders. Climbing bolt (9.1)
has passed the climbing pawl (5.1).
2. Press the pawl lock (5.4) upwards
by hand so that the climbing pawl is
activated. (Fig. 61)
3. Retract the hydraulic cylinder until the
climbing bolts (9.1) are positioned on
the climbing pawl (5.1).
Are all climbing pawls (5.1) engaged?
Fig. 61: Manually activated climbing pawl
From the rear
Section