TTR-07.1 Electromechanical Tripod Turnstile
9.5 Troubleshooting
Possible faults, which can be cleared by the users themselves, are listed in Table 4.
Table 4. Possible faults and remedy
Fault
Possible cause
Remedy
At the power-up the turnstile
doesn’t work, and there is
no light indication on the
turnstile housing and the
RC panel
No supply
voltage to the
CLB
Switch off the turnstile power supply from the AC
mains, open the turnstile housing cover, and remove
the outer panel. Check the power cable
serviceability and reliability of its connection to the
CLB “
XT3
” connector block
The turnstile is not
controlled in one of the
directions, and there is light
indication on the turnstile
housing and on the RC
panel
The CLB does
not receive a
control signal
from this
direction
Switch off the turnstile power supply from the AC
mains, open the turnstile housing cover, and remove
the outer panel. Check the RC panel / WRC kit /
ACS controller cable serviceability and reliability of
its connection to the CLB “
XT1.L
” and “
XT1.H
”
connector blocks
All other faults shall be cleared by the Manufacturer or his representatives only.