TTR-07.1 Electromechanical Tripod Turnstile
XT6
(
AntiPanic
) connector block to connect the electromagnet of automatic
anti-panic unblocking device;
J1
connector to select the turnstile control mode, the jumper is fixed — the pulse
control mode, the jumper is not fixed — the potential control mode. The jumper is
fixed at the factory before the delivery
J2
connector for programming.
Power
– power LED indicator on the control board.
Figure 4. Control Logic Board (CLB)
5.3 Control over the turnstile
5.3.1 The turnstile can be operated from the following control devices:
the RC panel;
WRC;
the ACS controller.
The above devices can be connected to the turnstile as follows:
any
device
separately;
in any combination with each other;
all devices simultaneously (in parallel).
Note:
At the parallel connection of the above devices to the turnstile the superposition
of the control signals from them may occur. In that case the turnstile response will
conform to response to the obtained combination of input signals. (App. A and B).
5.3.2 Connection of the devices stated in Clause 5.3.1 is made with the cable (5) to the
corresponding connector blocks
XT1.L
and
XT1.H
of the CLB in accordance with the
connection layout (Fig. 4 and Fig. 11).
5.3.3 The RC is connected to the contacts
GND
,
Unlock A
,
Stop
,
Unlock B
,
Led A
,
Led Stop
and
Led B
of the
XT1.L.
connector block.
5.3.4 WRC is connected to the contacts
GND
,
Unlock A
,
Stop
and
Unlock B
of the
XT1.L
.
connector block.
9