Assembly and Operation Manual
9 OPERATION INSTRUCTIONS
It is prohibited:
To operate the turnstile without following the operation safety requirements (see
Clause 7.2).
To move through the turnstile passage area any objects with dimensions
exceeding the width of the passageway.
To jerk hit barrier arms, turnstile housing and light indication display so as to
prevent their mechanical deformation.
To disassemble and regulate turnstile components.
To use abrasive or chemically active substances for cleaning for cleaning of the
turnstile external surfaces.
9.1 Power- up
Check the accuracy of all the connections and the power supply cable operability (see
Clause 8.4).
Connect the AC power cable (6) of the turnstile power supply (7) to the AC outlet with the
voltage and frequency rating according to the certificate for power supply.
Switch on the turnstile power supply (7). At the same time the “Red cross” pictogram on
the LED indication display of the turnstile housing and the indicator above the STOP
button on the RC panel (11) light up. Set the mounted barrier arm into the run position.
The arm should be fixed automatically.
9.2 Operating modes of the turnstile in pulse control mode
See Table 2 for the operating modes set from the RC PANEL and for the corresponding
indication. Please note the following:
-
Setting the operating modes for each direction is independent, i.e. setting
the operating mode for one direction does not change the operating mode set earlier
for the opposite one;
-
The “Single passage in the set direction” mode can be changed to the “Always free”
mode for the same direction, or to the “Always locked” mode;
-
The “Free passage in the set direction” mode can be changed to the “Always locked”
mode only.
At the turnstile power supply switching-on the reset sate of the turnstile is “Closed”.
In the “Single passage in the set direction” mode the turnstile will close automatically after
a person’s passage in the set direction. The turnstile will also close automatically, if the
passage is not made within 5 sec. In the “Bi-directional single passage” mode after the
passage in one direction the countdown of the passage waiting time (5 sec.) for the
opposite direction is recommenced.
Note:
Pressing the button on the RC panel corresponds to the low-level signal supply to
the contacts (“
Unlock A
”, “
Unlock B
” and “
Stop
”) of the “
XT1.L
” connector block
relatively to the contact “
GND
”.