3.6.
Options available on the valve
Mixing device
The valve can be equipped with a mixing device (
1
) whose function is to regulate the hardness of the
water at the outlet. The mixing can be set from 0% to 50% of hard water (i.e. 0 turn = 0% of hard water
with 100% of treated water and 1-½ turn = 50% of hard water with 50% of treated water).
Fast regeneration
This option allows the valve to regenerate in 90 minutes instead of 180 minutes.
Note
This valve can only be fitted with tanks up to 10”.
Low water usage piston (L.W.U.)
With this piston, water consumption during regeneration can be reduced.
½ turn
1½ turn
¾ turn
¼ turn
1¼ turn
0 turn