Installer Manual Fleck 4600 - MECH - System sizing
24 / 88
Ref. MKT-IM-027 / B - 01.06.2018
4.
System sizing
4.1. Recommendations
4.1.1. Injector/DLFC/BLFC-Valve configuration
4.2.
Sizing a softener (single unit)
4.2.1. Parameters to be considered
Whenever installing a softener, it is preferable to have full water analysis to ensure the inlet water
content will not affect the resin bed.
Note
Please consult your resin manufacturer specifications to ensure that no additional
pretreatment prior to softening is required.
Valve
type
Diameter
Resin
volume
Injector
DLFC
BLFC
[in]
L
DF
Color
UF
Color
[gpm]
DF [gpm] UF [gpm]
4600/
1600
1650
6
5 - 8
0
Red
N/A
N/A
0.8
0.125
N/A
7
9 - 14
1.2
0.25
8
15 - 21
1
White
1.5
9
22 - 28
2.0
10
29 - 42
2.4
12
43 - 56
2
Blue
3.5
0.50
13
57 - 70
4.0
Содержание Fleck 4600-MECH
Страница 1: ...FLECK 4600 MECH INSTALLER MANUAL WATER PURIFICATION ...
Страница 16: ...Installer Manual Fleck 4600 MECH Description 16 88 Ref MKT IM 027 B 01 06 2018 3 2 Outline drawing ...
Страница 59: ...Installer Manual Fleck 4600 MECH Maintenance Ref MKT IM 027 B 01 06 2018 59 88 ...
Страница 61: ...Installer Manual Fleck 4600 MECH Maintenance Ref MKT IM 027 B 01 06 2018 61 88 ...
Страница 74: ...Installer Manual Fleck 4600 MECH Spare parts 74 88 Ref MKT IM 027 B 01 06 2018 11 3 Valve parts list ...
Страница 76: ...Installer Manual Fleck 4600 MECH Spare parts 76 88 Ref MKT IM 027 B 01 06 2018 11 4 Meters parts list ...
Страница 87: ...Installer Manual Fleck 4600 MECH Disposal Ref MKT IM 027 B 01 06 2018 87 88 PAGE INTENTIONALLY LEFT BLANK ...
Страница 88: ...www pentairaquaeurope com ...