Softener fails to
draw brine
Plugged drain line flow control.
Clean drain line flow control.
Plugged injector and/or filter.
Clean or replace injector and/or filter.
Low water pressure.
Raise inlet pressure to 1.8 bar
minimum.
Internal valve leak.
Change seals & spacers and/or piston
assembly.
Bad programming.
Program correctly.
Power head not operating properly.
Change power head.
Controller cycles
continuously
Power head not operating properly.
Change power head.
Faulty microswitch or wiring loom.
Change microswitch or wiring loom.
Defective or badly set cycle cam.
Reposition or change cycle cam.
Drain flows
continuously
Foreign elements in the valve.
Clean valve and check it in the different
regeneration positions.
Internal valve leak.
Change seals & spacers and/or piston
assembly.
Valve blocked in brine refill or
backwash.
Defective or blocked motor.
Change motor and check gear teeth.
Power head not operating properly.
Change power head.
Problem
Cause
Solution
Содержание Fleck 4600-MECH
Страница 1: ...FLECK 4600 MECH INSTALLER MANUAL WATER PURIFICATION ...
Страница 16: ...Installer Manual Fleck 4600 MECH Description 16 88 Ref MKT IM 027 B 01 06 2018 3 2 Outline drawing ...
Страница 59: ...Installer Manual Fleck 4600 MECH Maintenance Ref MKT IM 027 B 01 06 2018 59 88 ...
Страница 61: ...Installer Manual Fleck 4600 MECH Maintenance Ref MKT IM 027 B 01 06 2018 61 88 ...
Страница 74: ...Installer Manual Fleck 4600 MECH Spare parts 74 88 Ref MKT IM 027 B 01 06 2018 11 3 Valve parts list ...
Страница 76: ...Installer Manual Fleck 4600 MECH Spare parts 76 88 Ref MKT IM 027 B 01 06 2018 11 4 Meters parts list ...
Страница 87: ...Installer Manual Fleck 4600 MECH Disposal Ref MKT IM 027 B 01 06 2018 87 88 PAGE INTENTIONALLY LEFT BLANK ...
Страница 88: ...www pentairaquaeurope com ...