Installer Manual Fleck 4600 - MECH - Programming
Ref. MKT-IM-027 / B - 01.06.2018
49 / 88
6.3.2. Set the number of days between two regenerations
No.
Operation
A
Push the pins (
1
) out to set up.
Note
There are two time clock wheels:
•
7 days: based on the week, number 1 will refer to Monday, number 7 to Sunday;
•
12 days: allows to set a regular interval every 2, 3, 4 or 6 days.
Note
Example for the following drawing, the regeneration will occurs on Monday and Thursday.