3.1. Technical
specifications
Design specifications/ratings
Valve body ............................................... Brass
Rubber components ............................... EP or EPDM
Weight (valve with controller) ................ 2.5 kg
Recommended operating pressure ....... 1.4 - 8.6 bar
Maximum inlet pressure ........................ 8.6 bar
Hydrostatic test pressure....................... 20 bar
Water temperature std........................... 1 - 43°C
Water temperature for HW volumetric .. 1 - 65°C
Water temperature for HW time clock... 1 - 82°C
Ambient temperature ............................. 5 - 40°C
Flow rates (3.5 bar inlet - valve only)
Continuous (Δp = 1 bar) .......................... 4.5 m
3
/h
Peak (Δp = 1.8 bar).................................. 5.9 m
3
/h
Cv*........................................................... 5.2 gpm
Kv*........................................................... 4.5 m
3
/h
Maximum backwash (Δp = 1.8 bar) ........ 1.6 m
3
/h
*Cv : Flow rate in gpm across the valve at a pressure drop of 1 psi at 60°F.
*Kv : Flow rate in m
3
/h across the valve at a pressure drop of 1 bar at 16°C.
Valve connections
Tank thread............................................. 2½" - 8NPSM
Inlet/Outlet.............................................. ¾" or 1"
Riser tube ............................................... 26.7 mm O.D., 1.05" tube
Drain line ................................................ ½" O.D.
Brine line (1650)...................................... ⅜"
Electrical
Power supply .......................................... 230 VAC, 50/60 Hz, 15 VA
Transformer output voltage ................... 24 VAC, 10 VA max.
Motor input voltage................................. 24 VAC
Controller input voltage ......................... 24 VAC
Controller max. power consumption .... 5 W
Protection rating..................................... IP 22
Transient overvoltages ........................... within the limits of category II
Pollution degree ..................................... 3
Temporary overvoltages must be limited in duration and in frequency.
Содержание Fleck 4600-MECH
Страница 1: ...FLECK 4600 MECH INSTALLER MANUAL WATER PURIFICATION ...
Страница 16: ...Installer Manual Fleck 4600 MECH Description 16 88 Ref MKT IM 027 B 01 06 2018 3 2 Outline drawing ...
Страница 59: ...Installer Manual Fleck 4600 MECH Maintenance Ref MKT IM 027 B 01 06 2018 59 88 ...
Страница 61: ...Installer Manual Fleck 4600 MECH Maintenance Ref MKT IM 027 B 01 06 2018 61 88 ...
Страница 74: ...Installer Manual Fleck 4600 MECH Spare parts 74 88 Ref MKT IM 027 B 01 06 2018 11 3 Valve parts list ...
Страница 76: ...Installer Manual Fleck 4600 MECH Spare parts 76 88 Ref MKT IM 027 B 01 06 2018 11 4 Meters parts list ...
Страница 87: ...Installer Manual Fleck 4600 MECH Disposal Ref MKT IM 027 B 01 06 2018 87 88 PAGE INTENTIONALLY LEFT BLANK ...
Страница 88: ...www pentairaquaeurope com ...