General malfunctions
Problem
Probable cause
Solution
Machine cycles (4
seconds)
1.
Chemical injector clogged
2.
Nozzle clogged
3.
Filter clogged
4.
Air leak
1. Replace the chemical injector.
2. Disassemble the nozzle and clean the elements.
3. Clean or replace the filter (see the maintenance section).
4. Locate air leak and repair.
Machine pulsates two
to three times per
second
Broken valve in the pump
Remove and replace pump valve (see the Repair section).
Chemical system malfunction
Problem
Probable cause
Solution
Injector(s) won’t draw
1.
Plugged wand nozzle
2.
Damaged wand nozzle
3.
Chemical pick-up filter
clogged
4.
Injector clogged
5.
Hose damaged
6.
Not adequate flow/
pressure
7.
Temperature too high
1.
Clean or replace nozzle.
2.
Replace nozzle.
3.
Check – clean or replace.
4.
Remove and clean injector.
5.
Replace hose.
6.
See low pressure section.
7.
Turn thermostat down.
Injectors fade in and
out
Water temperature too high
Recheck gas pressure and adjust to specifications.