![PEM SprayWand P-500 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/pem/spraywand-p-500/spraywand-p-500_manual_1523646021.webp)
19 |
P a g e
Initial startup procedure
1.
Inspect connections for any leaks and tighten if necessary.
2.
With the nozzle removed from the wand, turn on the Pump switch to
start the pump.
3.
Run the machine for 1 minute. Operate the trigger once or twice.
4.
Shut off the machine and install the nozzle.
5.
Check for high pressure leaks, and tighten connections if necessary.
6.
Operate the trigger mechanism to make sure the unloader valve that
operates the system is full of water.
7.
Turn the gas valve in back of the machine on.
8.
Turn on the fuel source. Check the thermostat setting.
9.
Turn on the Burner switch. Once the burner switch is turned on, the
pilot will attempt to light. The ignitor will try to light three times. Allow
time for the gas to get to the pilot. The burner switch may need to be
activated a few times to bleed the pilot line.
The ignition module will go into lockout mode after 15 seconds of not
lighting. To reset the ignition module, you will need to turn the burner
switch off and back on. Continue to do this until the temp light
illuminates. This indicates the pilot valve solenoid is open and the
igniter switch activated the pilot light. The Temp light will come on. The
system is ready to fire.
Note:
The system has series of safety checks that must be satisfied
before the Temp light comes on. If the Temp light is not on, the burner
will not fire. If the Temp light does not come on, refer to the
Troubleshooting section.
Note:
The igniter will light the pilot automatically when the Burner
switch is turned on. However, the burner only lights when the wand
trigger is pulled.
10.
When the Temp light is lit, which indicates the burner system is ready,
pull the wand trigger to activate the burner. The Flow light will light.
Note:
The gas control valve has a delay feature. It takes 4 to 7 seconds
for the burner to light after pulling the wand trigger. If the burner does
not light, refer to the Troubleshooting section.
11.
After pulling the wand trigger for 30 seconds to operate the burner, test
the flow switch by releasing the wand trigger. Confirm the burner
extinguishes immediately (you will be able to see that flame go out).