![PEM SprayWand P-500 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/pem/spraywand-p-500/spraywand-p-500_manual_1523646023.webp)
21 |
P a g e
Note:
When using the optional acidic injection system, the operator can switch
from wash mode to rinse mode by closing the siphon valve on the optional
injector between freshwater and seal rinse, but the rinse will be 1500 psi and
could cause the coating to wash away. Two wands are recommended.
Note:
The optional (second) injector gun and wand assembly are designed for
lower impingement than the main system. Lowering pressures in the rinse mode
and seal rinse modes will tend to build higher phosphate coating rates.
Your chemical injector has been factory set for proper injections. If chemical
does not come up, check the chemical filter on the end of the chemical hose.
Caution:
Chemicals not compatible with the system materials will cause
damage to the components down the line from the chemical injector. Ensure
the chemicals will not damage stainless steel, Buna-N, and Viton.
Warning:
High-pressure spray, detergents, fluid injector or debris
dislodged by the high-pressure spray can cause burns or other types of injuries.
To protect yourself, always wear full eye protection (preferably a face shield),
protective clothing, rubber gloves, and boots when operating the machine
.
Danger:
High pressure spray can damage the machine and cause
electrical shock. Never attempt to clean or wash down the machine using its
own spray gun. The machine is water protected but not water proof.