![PEM SprayWand P-500 Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/pem/spraywand-p-500/spraywand-p-500_manual_1523646048.webp)
46 |
P a g e
3.
Limed up heating coil.
4.
Burner control circuit faulty
keeping gas valve closed.
5.
Low temperature tap water
3.
Descale the unit.
4.
Check the circuit for loose wiring. Reestablish power.
5.
Increase water temperature.
Excessive temperature
output
1.
Temperature set too high
2.
Faulty thermostat
3.
Excessive gas pressure
1.
Decrease thermostat setting.
2.
Replace thermostat.
3.
Recheck pressure.
Intermittent ignition device problems
Problem
Probable cause
Solution
No ignition spark
1.
No voltage to module
2.
No voltage at pilot gas valve
1.
Ensure all safety switches are closed. Check all electrical connections.
2.
Ensure all safety switches are closed. Check all electrical connections.
Erratic main burner
operation, but the
ignition sparks, and the
pilot flame is on
3.
Ignition electrode needs
adjustment or is not
grounded
4.
Insulator cracked
5.
Pilot flame erratic
3.
Check the ignition electrode for gap and placement.
4.
Check the ceramic insulator for cracks.
5.
Check the pilot flame for flutter. Check the ground.
Pump malfunction and pressure delivery problems
Problem
Probable cause
Solution
Low pressure
1.
Worn or oversize spray
nozzle
2.
Clogged water inlet strainer
3.
Out of detergent (pump
sucking air through
detergent line)
4.
Air leak in inlet plumbing
5.
Belt slipping
6.
Dirt or foreign particles in
the valve assembly
7.
Worn or damaged inlet or
discharge valve.
8.
Inline filter plugged
9.
Coil scale
10.
Faulty unloader
1.
Replace worn nozzle.
2.
Clean or replace fouled strainers (in float tank).
3.
Restore detergent supply or close detergent shut-off valve.
4.
Locate air leak. Reseal connection or replace damaged part.
5.
Tighten or replace if damaged.
6.
Remove any dirt or particles.
7.
Replace worn valves.
8.
Clean inline filter, or replace if damaged.
9.
Descale coil.
10.
Replace unloader assembly.
Rough operation with
loss of pressure
1.
Restricted inlet plumbing or
air leak in inlet plumbing
2.
Damaged pump parts
3.
Damaged vacuum switch
1.
Ensure adequate water supply and supply hose. Repair clogged inlet
fittings.
2.
Replace any damaged pump parts clean out any foreign particles.
3.
Replace vacuum switch.
Water leakage in intake
manifold or crankcase
Worn manifold seals or
condensation inside the crankcase
Replace seals. Change the oil on a regular basis.
Содержание SprayWand P-500
Страница 2: ......
Страница 37: ...35 P a g e Figure 23 Pump exploded view ...
Страница 52: ...50 P a g e Figure 27 Electrical diagram ...