42 |
P a g e
Maximum HV lead length: 54”
Maximum operating temperature:
HV lead: 250° C
Wiring Harness (except sensor lead): 105° C
Relay contact load: 2 Amp. Inductive and 24 Vac, 60 Hz
Main valve control: Controlled by relay contact through the main valve
terminals.
Gas Valve
Before attempting any service on the heater gas control valve (see Figure 26),
note that only the service procedures outlined in the manual are approved by
the manufacturer. Replace the control valve if any other service or repair is
required.
Ensure the installer is a qualified serviceperson.
Shut off the gas supply before starting installation or service.
Do not connect the appliance before pressure testing
To prevent damage to the thermostat, do not short the gas valve
terminals.
Do not grip control the body with a wrench or vise. Use the inlet boss
only.
Leak test after installation or service. With gas flowing through the
control (main burner on), coat possible leak points (pipe and tubing
joints gasket edges, etc.) with a soap solutions. Bubbles indicate leaks.
Always turn the gas cock dial to full “ON” setting. Do not use it to adjust
gas flow.
When changing from natural to L.P. gas or vice versa, the burner and
pilot orifices must also be changed. Note that L.P. gas does not vent
upwards naturally.