![PEM SprayWand P-500 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/pem/spraywand-p-500/spraywand-p-500_manual_1523646029.webp)
27 |
P a g e
Pump belt
New belts will loosen after a short amount of use, and the tension must be
readjusted
1.
Measure belt defection at the longest span of belt, midway between the
pulleys. With a 25-lb vertical force applied, ensure the deflection is no
more than 1/2” to 5/8” (see Figure 13).
2.
If you are using a belt tension gauge, ensure that 100 to 110 lbs. is
registered on the spring scale when the pump is secured in the
operating position.
3.
To adjust the belt tension, loosen the four pump main frame attaching
bolt nuts one half to one turn. Turn the tension bolt nut clockwise to
tighten the belt or counterclockwise to loosen it.
4.
Tighten the mount-bolt nuts.
5.
Using a straight edge, verify the pump drive pulley alignment. If it is off,
adjust the position of the pump by loosening the pump mounting nuts,
adjusting the pump position and re-tightening the nuts.
Figure 13:
Measuring pump belt deflection
Inspect the belt for excessive wear, fraying and cracking at least once a month
or after every 100 hours of operation, whichever comes first. Replace damaged
or worn belts.
Note:
Install duel pump belts in matched sets. When belt replacement is
necessary, never replace a single belt in a set as the new belt will carry all the
load and fail rapidly.