Heating coil descaling
With any heating coil, water deposits can settle on the inner wall of the steel
pipe, causing several problems. These scale deposits act as an insulator, limiting
water temperature rise and causing hot spots where the coil starts to
deteriorate. Formations can break loose and clog some of the washer
components. The deposits also restrict flow through the coil and may eventually
completely plug it (see Figure 15).
Figure 15:
Coil deposits
The symptoms of a scaled coil are slow heating, inadequate heat rise, loss of
nozzle pressure, and a continuous motor overload. In areas with hard water,
plugging can occur in less than a month unless the coil conditioning system is
used.
Descale the coil as follows:
1.
Disconnect the hose leading from the unloader valve to the bottom of
the coil at the unloader. Connect the discharge hose from the descaler
to the hose leading to the coil.
2.
Disconnect the hose leading from the high-pressure coil to the
thermostat. Connect the free hose from the descaler pump to the
bottom of the hose. Do not put the hose in the drum of descaling
compound.
3.
Attach the descaler to a proper power source, and leave the descaler
pick-up hose out of the descaling compound. Start the descaler and run
for 10 seconds. Then insert the pick-up hose in the descaling compound
(this puts a slug of air in the coil to separate water from descaling
compound.)