![PEM SprayWand P-500 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/pem/spraywand-p-500/spraywand-p-500_manual_1523646032.webp)
30 |
P a g e
4.
Put the end of the free hose to a drain. Watch the hose discharge.
When the water is completed (i.e., when there is 10 seconds of air in
the line), turn the descaler off, and place the hose into the descaling
compound.
5.
Start the descaler and run for 10 minutes. Shut of the unit, and allow
the chemical to work for 5 minutes. Start the descaler and run for 5
minutes, and then shut off the descaler for 5 minutes. Restart the
descaler and run for 10 minutes.
6.
Repeat step 5 until the discharge chemical is no longer frothy, when the
chemical exits like it entered. This indicates the chemical no longer has
minerals to react with.
7.
Stop the descaler. Carefully lift the pick-up hose out of the descaling
compound. Start the descaler and run for 10 seconds to generator a
second air slug. Place the pick-up hose in fresh water. Watch the
discharge hose. When the air slug appears, turn off the descaler.
8.
Carefully lift the discharge hose out of the decaling drum and place it in
fresh water. Restart the descaler and run for 5 minutes. During this
time, the water will become very dirty. Change the water in the
container, and run the descaler another 6-7 minutes. If the second
water becomes very dirty, change the water again.
9.
Remove the descaler from the machine. Reattach the hose leading from
the unloader to the coil. Leave the free hose on the machine and run it
to the drain. Start the machine with the burner off, and run it for 10
minutes to flush the coil. Run the water into a clean 5-gallon pair for 50
seconds. If debris is found in the pail, flush for 10 more minutes.
10.
Remove the free hose. Reinstall the hose to the thermostat. The
machine is ready to be put back in service.
Machine exterior
Clean the exterior of the machine with a mild detergent.
Danger:
Do not clean or wash the machine using its own spray gun. The
machine is water protected but not water proof. Cleaning the machine in this
matter will increase the risk of serious or fatal electrical shock and damage to
the machine.
Содержание SprayWand P-500
Страница 2: ......
Страница 37: ...35 P a g e Figure 23 Pump exploded view ...