![PEM SprayWand P-500 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/pem/spraywand-p-500/spraywand-p-500_manual_1523646027.webp)
25 |
P a g e
Water inlet tank filter screen
The stainless steel screen located in the float tank (see Figure 7: Float Tank)
prevents foreign material from entering the pump. Check the screen frequently
to ensure that it does not clog.
Caution:
To prevent damage, never operate the machine with the filter
screen removed. Be sure to put the filter in place after cleaning it
.
Pump
Pump lubrication
The pump (see Figure 10) is pre-lubed at the factory. However, check the pump
oil level frequently as follows:
1.
Locate the oil site glass on the back side of the CAT pump. The site glass
is a clear circle with a red dot in the middle (see Figure 11). Ensure the
oil level is at the red dot. If the oil is low, remove the fill plug and add
oil.
2.
Fill the crankcase to the red dot on the site glass with
SAE 30 weight oil,
preferably with no detergent
. Do not overfill.
3.
Replace the fill plug.
Figure 10:
Pump