Figure 25:
Intermittent ignition device front with chart of fail codes.
Engineering data
Note:
Specifications subject to change without notice
Ignition means: Intermittent
Flame-establishing period: Continuous pilot burner
Flame failure response time:
Main gas shut off: 2.0 seconds (max)
Pilot gas: Continuous
Flame failure re-ignition time: 0.8 seconds max
Voltage: 24 Vac, 60 Hz
Note:
Total current drain for control will include gas valve loads in addition to
control module current drain.
Operating temperature range: 0° to 175° F
Spark voltage: 25kV Peak open circuit
Spark gap: 0.125” max
Spark type: Synchronous