Manual
77
8.3.9
Rough alignment of the laser beam
Position the laser transmitter (sensor S is set by default) as close as possible at the beginning of the
object (or at the first overlap point of the splice you want to measure, if more splices are used). Position
the receiver (sensor M is set by default) as close as possible to the transmitter. Adjust the position of the
transmitter, so that the laser beam maims the middle of the receiver. The laser position indicator on the
display shows the exact position. Move the receiver as far as possible (but only on the particular splice)
from the transmitter.
Adjust the position of the laser beam to the receiver with the help of the adjustment screws on the
transmitter once again. The laser beam should aim the middle of the receiver again. Move the receiver to
the first measurement point. Be sure that the right measurement point and the right splice (if used) are
selected.
If the laser beam is out of the aim on the receiver, repeat the adjustment process. Rough alignment
should be carried out once for each measurement object or each splice (if used).
Do not touch the transmitter or adjust the receiver in the course of the measurement.
Data not ready
(please wait)
No connection to the
sensors
Current measurement
number.
“-“ means no
measurement
Laser beam out of aim
Current point number
Laser beam position
indicator
Number of the saved
measurements for the
current point
Current result (Y-axis)
Current result (X-axis)
Neigungs-
anzeige