Manual
71
Rough alignment of the laser beam
Refer to
chapter 5.5 („Rough alignment“)
.
8.2.6
Carry out, view and replace measurements
To carry out a measurement, press
.
The saved measurement is now displayed in the measurement point screen. Please consider the
following:
If the inclination indicator is yellow, the current inclination is not acceptable (the minimum rotation of about
10° could be fallen short of. If the manual angle entry is activated, a yellow inclination indicator means
that the angle was not entered (in this case there is no pointer).
At least three measurements should be carried out to calculate the result. Save as many measurements
as possible (max. 36) in order to receive a result as accurate as possible. The minimum rotation angle
(amount of the particular rotations between the particular measurement points) cannot be under 170°. A
red square on the top right of the measurement point indicator means, that the total angle is too low.
To view the saved measurements, use
and
. To replace a measurement, select the according
measurement and press
.
A confirmation dialog will appear. Select “YES”.
Yellow indicates that the rotation
angle of the previous
measurement point is too small
(<10°)
A red square indicates, that the
total angle is too small (<170°).
Although, three
measurements
were carried out,
no result is
available,
because the total
rotation angle is
not acceptable