2) [t.Pr] pre‐purging with shielding gas time = 0.1s (by default)
a) 0.1 ... 25.0s (increment 0.1s)
3) [t.P0] post‐purging with shielding gas time = 1.5s (by default)
a) 0.1 ... 25.0s (increment 0.1s)
4) [t.uP] wire‐feeding speed fade‐in time = 0.1s (by default)
a) 0.1 ... 5.0s (increment 0.1s)
5) [t.dn] wire‐feeding speed fade‐out time = 0.1s (by default)
a) 0.1 ... 5.0s (increment 0.1s)
8. ATTENDANCE AND TECHNICAL MAINTENANCE
Attention!
Before opening the machine, switch it off and disconnect the mains
plug. Wait until internal circuits of the machine de‐energize (about 5 minutes), and
only then proceed with other actions. When leaving the machine, install a
restrictive plate which prohibits switching the machine on.
In order to ensure proper operation of the machine for many years, adhere to
several rules:
-
conduct inspection in accordance with safety practices within the established
time intervals (see “Safety rules” chapter);
-
if the machine is subject to heavy use, it is recommended to purge it with dry
compressed air once per six months.
Attention!
If the machine is purged from
a very short distance, electronic components may be damaged;
-
if the machine is very dust‐laden, clean channels of the cooling system
manually.
9. GENERATOR OPERATION MODE
The power source can be operated from a generator upon the following condition:
When
working with
electrode
Set current
value in MMA
and TIG modes
When working with wire
of specified diameter in
MIG/MAG mode
Minimum
generator
power
Ø
2
80А at most
Ø
0.6mm at most
2.9kVA
Ø3
120А at most
Ø
0.8mm at most
4.5kVA
Ø
4
160А at most
Ø
1.0mm at most
6.2kVA
Ø
5
200А at most
8.0kVA
Ø
6, low-
melting
250А at most
Ø
1.2mm at most
11.0kVA