- 33 -
PATON
MultiPRO series
DC MMA/TIG/MIG/MAG
Attention!
If button
3
is being held for more than 10 seconds, then the countdown
333 ... 222 ... 111 ... appears on the display, and you need to release the button
before this time has elapsed in order not to reset all settings of this mode to
standard factory settings. This task will be considered in Clause 6.3.
Similarly, when you press button
9
, the graphic name of the current function
of the wire‐feeding machine is displayed on the digital indicator on the right side.
Using buttons
8
, you can change it to a smaller or larger side.
If the menu is locked, as is the case with the function menu on the source, it is
enough to hold this button for more than 3.5 seconds.
6.2 SWITCHING TO THE REQUIRED WELDING MODE
Press button
4
to select the desired welding mode. The modes switch over
end‐around; it can be seen from lamps
4
on the front panel.
6.3 RESET OF ALL FUNCTIONS SETTINGS FOR THE CURRENT WELDING
MODE
There can be situations when the user becomes confused with the machine
settings. In order to reset them to standard factory values, just hold button
3
, that
is used to enter the function menu. If the machine has a system of protection
against unauthorized access to the function menu, then pressing the button
3
on
the source on the indicator on the left does not make any changes, that is, this
button is locked. In order to unlock it, it is necessary to keep it pressed for more
than 3.5 seconds. When unlocked, the indicator will display horizontal bars
indicating that the function menu is unlocked.
After successful unlocking, in order to reset the settings, it is enough to hold
button
3
continuously for more than 10 seconds. The countdown 333... 222... 111...
appears on the display, and upon reaching “000”, all settings of the current welding
mode will be updated to the factory settings. In order to reset all the settings of the
machine, you need to do this operation for each mode separately; this is done for
convenience, so as not to reset the second two modes, previously individually
configured by the user.
7. GENERAL LIST AND SEQUENCE OF FUNCTIONS
MMA welding mode
0) [-1-] – main displayed parameter CURRENT = 90A (by default)
a) 12 ... 250А (increment 1А)
1) [H.St] Hot Start power = 40% (by default)
a) 0[OFF] ... 100% (increment 1%)
2) [t.HS] Hot Start time = 0.3s (by default)