ELECTRICAL SPARK MAY CAUSE FIRE OR EXPLOSIVES:
Flammable items should be removed from the workplace. Do not perform
welding work on containers that contain gases, fuels, oil products or other
flammable materials. There is a risk of explosion of residue of these
products. When performing welding work in potentially explosive or fire
hazards, special rules must be observed that comply with national and
international standards. Firefighting equipment such as: (powder or snow
fire extinguishers, fire blankets) should be located near the workstation in
a visible, readily accessible place.
BOTTLE CAN EXPLODE:
Use only approved bottles and properly
functioning regulators. The cylinder should be transported and positioned
vertically. Protect the cylinder from heat, overturning and mechanical
damage.
WELDED MATERIALS MAY BURN:
In no case should you touch the
welded parts with bare hands. Always wear protective gloves when
operating the machine. The arc and splinters that develop during the burn
can cause skin burns. Wear protective gloves and pliers when touching or
moving the welded item.
ELECTRIC POWER SOURCES:
It is forbidden to work with damaged
welding wires or on wet substrates. Welding cables should be strong,
undamaged and insulated. Weakened connections and damaged cable
must be replaced immediately. Do not carry the device by pulling it by the
power cord or wires. Do not perform any maintenance work on the unit.
Removing the outside cover of the device while it is connected to the
network and using the device with the lid removed is forbidden.
NOISE ASSOCIATED WITH WELDING CAN BE HARMFUL:
The
welding arc formed during welding can emit sounds higher than 85dB for
- 8 hours of working time. Welders operating the equipment are obliged to
wear equivalent hearing protectors during work in accordance with the
Regulation of the Minister of Labor and Social Policy of 6 June 2014r. -
Dz. U. 2014 pos. 817. Pursuant to the Ordinance of the Minister of Health
on Social Welfare dated 09.07.1996 OJ No. 68 pos. 194 - The employer is
required to carry out research and measurement of factors harmful to
health.
CONFORMITY DECISION:
This device accomplish the
recommendation of the European CE Committee.
SAFETY MARK:
This device is suitable for mains power, for welding
work in an environment of higher standard of electric shock. It is
recommended that the power line be provided with a separate protection
against the shock absorber.