32 | P a g e
PATON
®
ADI 200 STANDARD TIG/MMA MIG/MAG
FREQUENCY PULSE
Current pulse frequency:
= 5.0 Hz (default value)
a)
10 … 500 Hz (adjustment 1 Hz)
DUTY CYCLE PULSE
Duty cycle (the ratio of the pulse length to the pulse repetition
period):
50% (default value)
a)
20 … 80% (adjustment 1%)
7.2. ARGON SHIELDED TUNGSTEN-ARC WELDING PROCESS (TIG)
0) [-2-]
Basic indicated parameter:
welding current = 100 A (default value)
a)
8 ... 160 А (adjustment 1А) for ADI-160S
b)
10 ... 200 А (adjustment 1А) for ADI-200S
BUTTON MODE
Tryb na przycisku uchwytu
[2T] (default value)
a)
[LFt] - contact arc starting, function TIG-LIFT
b)
[2t] - contactless arc starting, function TIG-2T
c)
[4t] - contactless arc starting, function TIG-4T
TIME PRE GAS
Period of preweld gas purging: 2.0 s (
default value
)
a)
0.5 … 25.0 s (positive or negative increment 0.1 s)
TIME POST GAS
Period of post weld gas purging: 3.0 s
(default value)
a)
1.0 … 25.0 s (positive or negative increment 0.1 s)
PRIMARY ARC
Initial current (pilot arc current): 15 A (default value)
a)
8 … 40 A (positive or negative increment 1 A) for ADI-160S
b)
10 … 40 A (positive or negative increment 1 A) for ADI-200S
POST CRATER ARC
Crater welding current: 20 A
(default value)
a)
8 … 60 A (positive or negative increment 1 A) for ADI-160S
b)
10 … 60 A (positive or negative increment 1 A) for ADI-200S
TIME UP ARC
Period of current rise: 1.0 s
(default value)
a)
0.1 … 5.0 s (positive or negative increment 0.1 s)
TIME DOWN ARC
Period of current reduction: 2.0 s (default value)
a)
0.1 … 5.0 s (positive or negative increment 0.1 s)
POWER PULSE
Current pulse amplitude: OFF
(default value)
a)
0 [OFF] … 80 % (positive or negative increment 1 %)
FREQUENCY PULSE
Current pulse frequency: 5.0 Hz (
default value)
a)
0.2 … 50 Hz (positive or negative increment 1 Hz)
DUTY CYCLE PULSE
Duty cycle (the ratio of the pulse length to the pulse repetition period):
50 % (
default value
)
a)
20 … 80 % (positive or negative increment 1 %)