4 | P a g e
PATON
®
ADI 200 STANDARD TIG/MMA MIG/MAG
ATTENTION!
When connecting the welding unit to the power
distribution board (at a temperature of 25 ºC), take into account through-the-
wall wiring and the lengths of extension cables.
Electrode
diameter for a
MMA welding
process (mm)
Set current for
MMA and TIG
welding processes
(A)
Electrode wire
diameter for a
MIG/MAG welding
process (mm)
Cross-section
area of the
power cable
conductor
(mm
2
)
Maximum
cable length
(m)
PATON ADI 160 STANDARD
Ф
2 mm
Not more than 80 A
Not more than
Ф
0.6
1
75
1,5
115
2
155
2,5
195
4
310
Ф
3 mm
Not more than 120 A Not more than
Ф
0.8
1,5
75
2
105
2,5
130
4
205
6
310
Ф
4 mm
Up to 160 A
Not more than
Ф
1.0
2
75
2,5
95
4
155
6
230
PATON ADI 200 STANDARD
Ф
3 mm
Not more than 120 A Not more than
Ф
0.8
1,5
75
2
105
2,5
130
4
205
6
310
Ф
4 mm
Not more than 160 A Not more than
Ф
1.0
2
75
2,5
95
4
155
6
230
Ф
5 mm
Up to 200 A
Not more than
Ф
1.0
2,5
60
4
100
6
150