P
AGE
23
4.5.3.2 MOVEMENT IN THE PROGRAM MODE
Each time the DOWN key is depressed while a parameter code is being displayed, such as
inPS
, another parameter code will be displayed.
Depressing the SCROLL key while a parameter code is displayed will cause the parameter
value to appear. Depressing the SCROLL key with a parameter value displayed will cause
the next parameter code to appear.
Depressing the UP key while a parameter code is being displayed will exit the Program mode
and
Prog
will appear in the display. Use the DOWN key to re-enter the mode, or the
SCROLL key to proceed to another mode.
4.5.3.3 ONE PEN INSTRUMENTS
For instruments specified and provided with only one pen, all configuration and operating
parameters and values will appear in the upper display, which is dedicated to Pen 1 and Unit
parameters. This is the only display provided.
PEn2
will not appear.
4.5.3.4 TWO PEN INSTRUMENTS
Instruments specified and provided with two pens require configuration of each pen.
4.5.3.5 PROGRAM MODE CONFIGURATION
Refer to Table 4-2 (page 26) for configuration procedures for the Program mode. All possible
parameters are shown for illustration purposes. Only those parameters applicable to each
respective pen and the unit will actually be shown.
4.5.4 ALARM SET MODE CONFIGURATION PROCEDURE
The Alarm Set mode allows the entry, review or altering of any of the alarm settings. Para-
meters to be configured will be only those that are applicable as determined by the hardware
provided or as assigned in the Program mode.
Review the entry procedure and the configuration procedures in Table 4-3 (page 30). Use
the "Your Setting" column in the table to record your programming.
4.5.4.1 ENTERING THE ALARM SET MODE
From the Operation or any other mode code, depress the SCROLL key until
ASEt
is dis-
played. With
ASEt
in the top display depress the DOWN key to enter the mode. If
ASEt
does not appear, then the mode has been disabled. Refer to Table 4-1 (page 25) for Enable
mode instructions.
4.5.4.2 MOVEMENT IN THE ALARM SET MODE
Each time the DOWN key is depressed while a parameter code is being displayed another
parameter code will be displayed.
Depressing the SCROLL key while a parameter code is displayed will cause the parameter
value to appear. Depressing the SCROLL key with a parameter value displayed will cause
the next parameter code to come up in the display.
Depressing the UP key while a parameter code is being displayed will exit the Alarm Set
mode and
ASEt
will appear in the display. Using the SCROLL key at this point will allow you
to proceed to any other mode.
4.5.4.3 ALARM SET MODE CONFIGURATION
Refer to Table 4-3 (page 30) for configuration procedures for the Alarm Set mode. All
possible parameters are shown for illustration purposes. Only those parameters applicable to
each respective pen will actually be shown.
Содержание MRC 7800