FIGURE 2-4
Volt, Millivolt and milliamp Input
Make the volt, millivolt or milliamp conections as shown below. Use TB4 for Pen 1 and TB5
for Pen 2. Terminal 1 is positive and terminal 2 is negative. Be sure that input conditioning
jumpers are in the correct positions for the input being connected. See Appendix A-1 (page
46).
FIGURE 2-5
Transmitter Power Supply
If the isolated 24 VDC regulated transmitter power supply has been specified, the connections
should be made as shown. Connections are made using TB3, terminal 1 is positive and
terminal 2 is negative. The power supply is capable of providing the power needed by up to 2
transmitters.
1 2 3 4 5
+ -
TB4 or TB5
SHIELDED
TWISTED
PAIR
SOURCE
+ -
MAY BE
GROUNDED
OR
UNGROUNDED
SHIELDED
TWISTED
PAIRS
1 2 3 4 5
+ -
TB4 or TB5
TB3
1 2
+ -
+ -
1 2 3 4 5
+ -
TB4
TB3
1 2
+ -
1 2 3 4 5
+ -
TB5
+ -
+ -
TWO WIRE
TRANSMITTERS
TWO WIRE
TRANSMITTERS
TWO WIRE
TRANSMITTERS
NOTE: Fault Detection
Not Functional for 0-5V