13
VitaPump Specifications:
Mechanical:
Dimensions:
Width: 5.75 in (14.6cm); Height: 8.5 in (212.6); Depth: 11in (27.9)
Weight:
14 lbs (6.4kg)
Enclosure:
Aluminum / Steel; Corrosion Resistant, Recessed Handle.
Pump Head / Motor Options:
1.
Tandem 1081 peristaltic pump head with 160-RPM motor
, thin-walled (0.060”) pump
tubing: #13 & 14. Flow Range: 0.5 to 45.0 ml/min. max back pressure: 30 psi.
2.
FMI Q1 Sanitary Piston head
, with 160-RPM motor, Stainless Steel body, Ceramic
Piston and Cylinder. Tubing: #17 Tygon Food Grade, 1/4" ID. Flow Range, 0.5 to 42 ml/min
Electrical:
Power:
90 - 264 V
, 47-63 Hz, 150 VA, listed Class 2 switching power supply.
Double fused: 1A-T, 250V (CE: IR35A 250V
).
Battery:
CR1220, used to support the internal clock only, not user serviceable.
Motor:
Choice of three (3) motors: 8, 160 and 600 RPM at 24V
, 3.8 Amperes,
Variable Pump Speed optically encoded servo-controlled motors.
Encoder:
100 lines per / rev. for 600-RPM motor. 120 lines per / rev. for 8 and 160
RPM
motors.
I/O Ports:
“Printer”,
Female DB9 connector for data collection with Printer or PC.
“S1”,
Male DB9 connector for RS-232 connection to an electronic scale.
“S2”,
Male DB9 connector, Not utilized on PureTec. Do not remove the cover.
“
S3”,
Male DB9 connector, Not utilized on PureTec. Do not remove the cover.
“External I/O”,
Female DB37 connector used for remote On/Off control of
PureTec via footswitch, or for Analog interface with SciCon or other 4-20 ma
source, A1, A2, A3.
“V”,
Female DB15 connector, Not utilized on PureTec.
“
Temperature
”, 2 pin Conxall connector for SciTemp™ disposable
Temperature
Sensor.
“P1, P2, P3”
, RJ11 connectors used for SciPres disposable Pressure Sensors.
“USB”
, USB-A connector, used for RS-232 data collection with a PC.
“
Ethernet
”, RJ-45 connector, used for Modbus TCP/IP connection with system.
(when
available)
Display:
Two line LCD, 20 characters each, back-lit.
Data Entry
: Membrane keyboard with auditory feedback.
Содержание VitaPump
Страница 1: ...VitaPump System Installation Operation Maintenance Instructions ...
Страница 19: ...19 ...
Страница 21: ...21 2 0 Vitamin Metering Edit Alarm ...
Страница 23: ...23 3 0 Metering Exec ...
Страница 24: ...24 4 0 Setup Edit ...
Страница 34: ...34 Appendix A Tandem Pump Head Installation and Maintenance ...
Страница 37: ...37 TANDEM Dual Channel Peristaltic Pump Parts Identification ...
Страница 39: ...39 Appendix B FMI Q1 Pump Head Installation and Maintenance ...
Страница 40: ...40 ...
Страница 41: ...41 ...
Страница 42: ...42 ...
Страница 43: ...43 ...
Страница 44: ...44 ...