USB Port:
Used for connection to a PC, providing a Com Port. Can be used for data
collection as an alternative to the Printer port. The driver is included on the CD that contains
this
manual.
Ethernet Port:
Disabled.
3.1 External I /O Port:
A TTL alarm
output
(two-wire cable between pin 9 and pin 30) allows you
to monitor VitaPump alarm conditions. (5.0VDC output control signal, requires use of a solid state
relay that will trip at 3 volts; is low (0 volts) when off, and high (5 volts) when tripped.
An additional TTL
output
will provide you with a similar signal to provide a Status Signal that is On
(5 volts) when the VitaPump’s motor runs, and Off (0 volts) when it isn’t. (two-wire cable between
pins 12 & 31) (5.0VDC output control signal, requires use of a solid-state relay that will trip at 3
volts)
A TTL input (two-wire cable between pin 19 and pin 37) allows remote “RUN” / “STOP” by means of
dry contact closure. This last feature is set to LEVEL (contact closure) by default for input from your
control system. It can be set to PULSE to allow use of the RUN button in Metering Mode.
All three cables are usually assembled as a set into one head shell and tested at Parker prior to
shipment.
Содержание VitaPump
Страница 1: ...VitaPump System Installation Operation Maintenance Instructions ...
Страница 19: ...19 ...
Страница 21: ...21 2 0 Vitamin Metering Edit Alarm ...
Страница 23: ...23 3 0 Metering Exec ...
Страница 24: ...24 4 0 Setup Edit ...
Страница 34: ...34 Appendix A Tandem Pump Head Installation and Maintenance ...
Страница 37: ...37 TANDEM Dual Channel Peristaltic Pump Parts Identification ...
Страница 39: ...39 Appendix B FMI Q1 Pump Head Installation and Maintenance ...
Страница 40: ...40 ...
Страница 41: ...41 ...
Страница 42: ...42 ...
Страница 43: ...43 ...
Страница 44: ...44 ...