27
4.4 Printer Documentation:
The VitaPump will output data to a printer or a PC at periodic intervals for archival purposes. The
following is an example of that data, and an explanation of the abbreviations used.
VITAMIN D = 6.00g/m: ALARMS: BW=2; PR=3; LIMIT:BW=0.000kg
T
= 00.00;
TW
= 0.000kg;
BW
= 0.000kg;
PR
= 6.00g/m
ST
=START
T
= 00.05;
TW
= 0.030kg;
BW
= 0.030kg;
PR
= 6.00g/m
ST
=RUN
T
= 00.10;
TW
= 0.060kg;
BW
= 0.060kg;
PR
= 6.00g/m
ST
=RUN
T
= 00.15;
TW
= 0.090kg;
BW
= 0.090kg;
PR
= 6.00g/m
ST
=RUN
T
= 00.20;
TW
= 0.120kg;
BW
= 0.120kg;
PR
= 6.00g/m
ST
=STOP
AL
= PR
T
= 00.21;
TW
= 0.120kg;
BW
= 0.120kg;
PR
= 6.00g/m
ST
=EXIT
VITAMIN D
= Several different labels available to choose from under Mode:Setup, SET
LABEL.
T
TIME:
Relative time counter, starts/resets at beginning of batch metering program.
Can be set to actual time, and print the current date in header. See example below.
TW
TOTAL WEIGHT,
long term cumulative counter, can be reset in Mode:Setup, CLEAR
TOTAL.
BW
BATCH WEIGHT
, cumulative batch weight counter, resets at beginning of batch metering
program, usually when new vitamin bottle is placed on balance.
PR
PUMP RATE
, gravimetric metering rate expressed in grams/minute ST = STATUS,
Pump Status (Start, Run, Pause, Run, Exit)
AL
ALARM,
Print out of Alarm condition. AL=PR represents Pump Rate Alarm, AL=BW
represents Batch Weight Alarm.
NOTE:
Three alarm levels are defined and displayed in the program header of the printout as
follows: 1 =
Off
(Deactivated); 2 =
Alert
(Metering continues, auditory beep/5V output to remote
alarm occurs); 3 =
Pump Stop
(Stops the pump, auditory beep/5V output to remote alarm occurs).
Immediate data printout occurs when RUN, STOP or EXIT keys are pressed, and when an alarm
occurs. All other printouts occur at a user definable frequency in minutes:seconds. (Mode: Setup,
Printer, Time)
If you choose to do so, you can go to Mode: Setup, Clock and enter the Time of Day (24hr format),
Day, Month, and Year. Under Mode: Setup, Clock, Print Enable, select Time of Day instead of
Relative Time. The data printout will change to look like the following, and drastically ease your
record keeping:
VITAMIN D = 6.00g/m: ALARMS: BW=2; PR=3; LIMIT:BW=0.000kg 10/29/02
T
= 16:30;
TW
= 0.000kg;
BW
= 0.000kg;
PR
= 6.00g/m ST=START
T
= 16:35;
TW
= 0.030kg;
BW
= 0.030kg;
PR
= 6.00g/m
ST
=RUN
T
= 16:40;
TW
= 0.060kg;
BW
= 0.060kg;
PR
= 6.00g/m
ST
=RUN
T
= 16:45;
TW
= 0.090kg;
BW
= 0.090kg;
PR
= 6.00g/m
ST
=RUN
T
= 16:50;
TW
= 0.120kg;
BW
= 0.120kg;
PR
= 6.00g/m
ST
=STOP
AL
= PR
T
= 16:51;
TW
= 0.120kg;
BW
= 0.120kg;
PR
= 6.00g/m
ST
=EXIT
Содержание VitaPump
Страница 1: ...VitaPump System Installation Operation Maintenance Instructions ...
Страница 19: ...19 ...
Страница 21: ...21 2 0 Vitamin Metering Edit Alarm ...
Страница 23: ...23 3 0 Metering Exec ...
Страница 24: ...24 4 0 Setup Edit ...
Страница 34: ...34 Appendix A Tandem Pump Head Installation and Maintenance ...
Страница 37: ...37 TANDEM Dual Channel Peristaltic Pump Parts Identification ...
Страница 39: ...39 Appendix B FMI Q1 Pump Head Installation and Maintenance ...
Страница 40: ...40 ...
Страница 41: ...41 ...
Страница 42: ...42 ...
Страница 43: ...43 ...
Страница 44: ...44 ...