5.3
MEMBRANE ELEMENT INSTALLATION OR REPLACEMENT
The membrane when the pressure is at maximum and the TDS is unacceptable.
Call
Out
Description
Qty Parker Part #
1
VESSEL, FRP,3021,1 KPSI, W/O ENDCAPS
1
50012002
2
ELEMENT, BRACKISH WATER, LE-3021
1
33-0321
3
VESSEL END PLUG, ACETAL,3021,1/4 FNPT PORTS
1
51012001
4
VESSEL END PLUG, ACETAL,3021,1/4 FNPT PORTS
1
51012001
5
SC SOC CAP 1/4-20 X 3/4 SS
6
061162345012
6
O-RING 230 BRINE 3" END PLUG
2
2614014900
7
O-RING 116 PRODUCT
4
2614010100
8
BRINE SEAL (SUPPLIED WITH MEMBRANE)
1
9
SEGMENT RING AW (SET)
2
20201030000
Table 5.2 – Pressure Vessel Parts List.
CAUTION
Membranes are specifically designed for RO applications. Use of non-
approved membranes will void the RO unit warranty.
NOTE
It is recommended to replace all Brine and Product Water O-Rings
attached to the End Plugs within the High Pressure
Vessel Assembly each time the Reverse Osmosis Membrane
Element is removed or replaced.