Call Out
Description
Qty
Parker Part #
1
ELEMENT PRE- FILTER 10-25
2
0801130257
2
O-RING 237 BLUE HOUSING
2
2614010473
Table 5.1 - Filter Parts List.
CAUTION
Parker filter cartridges are specifically designed for RO applications and
constructed with a carbon attractive chlorine. Use of non-approved
cartridges will void the RO unit warranty.
Replace the filter element(s) using the following procedure:
1)
Secure the RO unit. Close the raw water supply (external) to RO unit.
2)
Remove bowl from filter housing.
3)
Remove the filter element.
4)
Replace the filter element and install a new element.
5)
Reinstall a new filter element. Inspect O-ring and replace as necessary.
6)
Reinstall the filter bowl and tighten.
7)
After the filter element has been changed, operate the RO unit and check for
leaks.