1.0
SYSTEM DESCRIPTION
The Parker Hannifin UltRO Clear System is a purification system that
uses direct feed water from Sea water RO unit or Dock water to produce spot free ultra-pure
water. This unit produces UltRO Clear quality water with salt concentrations of <20 PPM
TDS ppm by removing approximately 99% of the dissolved salt in potable water.
1.1
SPECIFICATIONS
1.1.1
PERFORMANCE CHARACTERISTICS
Parameter
Specification
Permeate Flow (1):
4 m
3
/day. (0.73 GPM) Potable
Feed Flow:
0.5 m
3
/hr. (3 GPM) Normal
Concentrate Flow:
0.3 m
3
/hr. (1.3 GPM)
Feed water TDS
Less than 20 ppm TDS
Design water Temperature:
25 °C (77 °F) Production shall not decrease
more than 3% for each °C temperature decreasing
of sea water feed.
Product Pressure:
0-2 BAR (0-30 PSI)
Max. Operating Pressure:
28 BAR (400 PSI)
Design RO element pressure:
10.5 BAR (150 PSI)
Max. feedwater residual chlorine:
<1 ppm
Membrane type:
Thin film composite
(1)
Raw water temperatures less than 25°C (77
º
F) will result in less than rated product water output.
Conversely, higher raw water temperatures will result in higher than rated output.
Table 1.0 - Performance Specification