3.4
OPERATIONAL DESCRIPTION
3.4.1
ULTRO CLEAR SYSTEM
Potable water supplied to the intake of the Parker RO ULTRO CLEAR unit will
initially flow through the
Relief Valve
. This valve is set at 60 psi (4.15 Bar).
Once through the relief valve, the potable water is supplied to the
filtration system
.
The inlet pressure is monitored by
feed pressure switch, PSLL-50
this protects the
system from low pressure and will shut down the system. The water then flows into the
two
carbon/sediment filters, AC-20A/B,
which is designed to reduce raw water
turbidity to a nominal 5 microns in diameter and remove free chlorine that may be
present in the water. The discharge pressure from the filter housing is monitored by a
pressure gauge, PI-20
.
Figure 3.2 – System Front Panel - #1