Installing the Drive
3-6
650G AC Drive
Through-Panel Mount Product/Application (Frame D)
(Europe: IP2x, USA/Canada: Open Type).
The drive, without the top cover fitted, can be mounted in a suitable cubicle.
J
K
L
M
ISOLATED FORCED AIR FLOWS
panel
P
N
Figure 7 Air Clearance for a Through-Panel Mount Product/Application
Model Recognition
Clearances for Through-Panel Mount Standard
Product (mm)
Through-Panel
Dimensions
J
K
L
M
N
P
Frame D
15 LHS, 5 RHS
25
100
100
141
104
Through-Panel Mount
Bracket Assembly (Frame D)
The through-panel kit is available as a separate
item, part number LA465048U003.
Through-panel mounting a drive in a cubicle
allows you to use a smaller cubicle because
much of the heat generated by the drive is
dissipated outside the cubicle.
Cut the panel aperture to the dimensions
given in the drawing at the end of this
chapter.
Screw the top and bottom brackets to the
drive as shown, torque to 4Nm. When in
position, these complete a mating face for the
panel around the drive.
Fit the top and bottom gaskets to the panel,
aligning the gasket holes with the holes in
the panel for fixing the drive. Fit two side
gaskets around the panel aperture so that an
air-tight seal will be made between the drive
and the panel; 2 extra side gaskets are
provided.
Offer up the drive to the panel and secure.
Refer to Through-Panel Cutout Details,
page 3-9.
panel
www.comoso.com
Содержание 650G series
Страница 2: ...www comoso com ...
Страница 30: ...3 9 Installing the Drive 650G AC Drive Through Panel Cutout Details www comoso com ...
Страница 32: ...3 11 Installing the Drive 650G AC Drive Duct Kit Installation Diagram www comoso com ...
Страница 49: ...Installing the Drive 3 28 650G AC Drive Figure 3 14 Footprint Bookcase Mounting Filters generic www comoso com ...
Страница 153: ...Applications 13 12 650G AC Drive www comoso com ...