![Parker 650G series Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/parker/650g-series/650g-series_product-manual_755633024.webp)
3-3
Installing the Drive
650G AC Drive
Minimum Air Clearance (Frame C)
Cubicle-Mount Product/Application (Frame C)
(Europe: IP2x, USA/Canada: Open Type).
The drive, without the top cover fitted, must be mounted in a suitable cubicle.
Control
Heat
Sink
J
K
L
M
FORCED AIR FLOW
Figure 2 Air Clearance for a Cubicle-Mount Product/Application
Model Recognition
Clearances for Standard Product without Top Cover (mm)
J
K
L
M
Frame
C
15 15 70 70
Wall-Mount Product/Application (Frame C)
(Europe: IP2x plus IP4x top surface protection, USA/Canada: Type 1).
Wall-mounted 650G units
must
have the top cover correctly fitted. The top cover fixing screw
has a maximum tightening torque of 1.5Nm (1.2Nm recommended).
Top Cover
J
Control
Heat
Sink
K
L
M
FORCED AIR FLOW
Figure 3 Air Clearance for a Wall-Mount Product/Application
Model Recognition
Clearances for Standard Product fitted with Top Cover (mm)
J
K
L
M
Frame
C
20 15 70 70