B. Standards Compliance for SNMP Traps
B-2
May 2002
8700-A2-GB20-40
For a unit defined as an NTU running IP Conservative software, all traps have at a
minimum a variable binding of the Super Overloaded ifIndex (SOI). The formula
for the SOI is:
((LTU Slot Number) * 1,000,000)
+ ((LTU DSL Port Number) * 1,000)
+ the NTU’s ifIndex.
warmStart
authenticationFailure
linkUp and linkDown
The link SNMP traps are:
linkUp – The unit recognizes that one of the communication interface is
operational.
linkDown – The unit recognizes that one of the communication interface is not
operational.
The network and synchronous port interfaces (physical sublayer) are represented
by an entry in the MIB-II interfaces table and supported by the DS1 MIB.
SNMP Trap
Description
Possible Cause
warmStart
The unit has reinitialized
itself.
The trap is sent after the unit
resets and stabilizes.
No variable bindings.
Reset command.
Power disruption.
SNMP Trap
Description
Possible Cause
authenticationFailure
Failed attempts to access the
unit.
Variable bindings:
devAuthentication
FailureIPAddress
(Health & Status MIB)
Returns zero if the IP
address is unknown or the
failure came from the
terminal port.
Three unsuccessful attempts
were made to enter a correct
login/password combination.
Содержание Hotwire 8779
Страница 22: ...2 Using the Asynchronous Terminal Interface 2 10 May 2002 8700 A2 GB20 40...
Страница 36: ...3 Initial Startup and Configuration 3 14 May 2002 8700 A2 GB20 40...
Страница 44: ...4 Cross Connecting Ports 4 8 May 2002 8700 A2 GB20 40...
Страница 52: ...6 Security 6 6 May 2002 8700 A2 GB20 40...
Страница 96: ...9 Transferring Firmware and Configurations Using TFTP 9 6 May 2002 8700 A2 GB20 40...
Страница 148: ...C Connector Pin Assignments C 4 May 2002 8700 A2 GB20 40...
Страница 150: ...D Technical Specifications D 2 May 2002 8700 A2 GB20 40...
Страница 182: ...Index IN 6 May 2002 8700 A2 GB20 40...