A. Configuration Options
8700-A2-GB20-40
May 2002
A-11
Primary Clock Source
Possible Settings: Internal, G.703
Default Setting: Internal
Determines the primary clock source for the unit in Bypass mode.
Primary Clock Source is available only when the unit is configured as an LTU. When
configured as an NTU, the clock source is derived from the DSL.
Internal – Timing is derived from the internal oscillator.
G.703 – Timing is derived from the G.703 interface.
Table A-5.
G.703 Interface Options – Model 8779 (3 of 3)