7. Monitoring and Troubleshooting
8700-A2-GB20-40
May 2002
7-7
Self-Test Results Messages
The results of the last power-on or reset self-test appear in the middle column of
the System and Test Status screen.
Table 7-2.
Self-Test Results Messages (1 of 2)
Message
What Message Indicates
What To Do
CPU Fail
The Central Processing Unit
failed internal testing.
1. Reset the unit and try again.
2. Call your service
representative for
assistance.
CPU CPLD Fail
The Complex Programmable
Logic Device serving the
Central Processing Unit
failed.
Data Path Fail, Pt
n
The port shown failed to loop
data on the full data path test.
DeviceFailed
One or more of the unit’s
integrated circuits has failed
device-level testing.
DSL
Framer
x Fail
Th e DSL framer for Ports
1– 4 (Framer A) or
5 – 8 (Framer B) failed.
DSL xcvr Fail, Pt
n
The DSL transceiver failed
on Port
n.
DSX-1 Failed, Pt
n
The unit failed to internally
loop data on the DSX-1
Port
n.
DTE
Framer
x Fail
The DTE framer for Ports
1– 4 (Framer A) or
5 – 8 (Framer B) failed.
DTE LIU
x Fail
The DTE Line Interface Unit
for Ports 1– 2 (LIU A),
3 – 4 (LIU B), 5 – 6 (LIU C), or
7 – 8 (LIU D) failed.
EEPROM Fail
The unit failed Electrically
Erasable Programmable
Read-Only Memory
verification.
Failure
xxxxxxxx
An internal failure occurred.
(xxxxxxxx represents an
8-digit hexadecimal failure
code for use by service
personnel.)
Record the failure code
and contact your service
representative.
Содержание Hotwire 8779
Страница 22: ...2 Using the Asynchronous Terminal Interface 2 10 May 2002 8700 A2 GB20 40...
Страница 36: ...3 Initial Startup and Configuration 3 14 May 2002 8700 A2 GB20 40...
Страница 44: ...4 Cross Connecting Ports 4 8 May 2002 8700 A2 GB20 40...
Страница 52: ...6 Security 6 6 May 2002 8700 A2 GB20 40...
Страница 96: ...9 Transferring Firmware and Configurations Using TFTP 9 6 May 2002 8700 A2 GB20 40...
Страница 148: ...C Connector Pin Assignments C 4 May 2002 8700 A2 GB20 40...
Страница 150: ...D Technical Specifications D 2 May 2002 8700 A2 GB20 40...
Страница 182: ...Index IN 6 May 2002 8700 A2 GB20 40...