B. Standards Compliance for SNMP Traps
8700-A2-GB20-40
May 2002
B-5
enterpriseFallback
AutoRate(13)
After a loss of signal, the
unit resynchronized to a
lower rate than the last
known rate.
Variable bindings:
ifIndex (RFC 2863)
ifAdminStatus
(RFC 2863)
ifOperStatus (RFC 2863)
ifType (RFC 2863)
Variable line conditions.
enterprisePrimaryClockFail
Clear(101)
The LTU has recovered and
is using its primary clock
source.
No variable bindings.
enterpriseSecondaryClock
FailClear(104)
The LTU has recovered and
is using its secondary clock
source.
No variable bindings.
enterpriseTestStop(105)
All tests have been halted.
Variable bindings:
ifIndex (RFC 2863)
ifAdminStatus
(RFC 2863)
ifOperStatus (RFC 2863)
ifType (RFC 2863)
ifTestType (RFC 2863)
All tests on an interface have
been stopped by timeout or
an Abort All Tests command.
enterpriseFallback
AutoRateClear(113)
After an AutoRate fallback
condition, the unit
resynchronized to the last
known rate.
Variable bindings:
ifIndex (RFC 2863)
ifAdminStatus
(RFC 2863)
ifOperStatus (RFC 2863)
ifType (RFC 2863)
SNMP Trap
Description
Possible Cause
Содержание Hotwire 8779
Страница 22: ...2 Using the Asynchronous Terminal Interface 2 10 May 2002 8700 A2 GB20 40...
Страница 36: ...3 Initial Startup and Configuration 3 14 May 2002 8700 A2 GB20 40...
Страница 44: ...4 Cross Connecting Ports 4 8 May 2002 8700 A2 GB20 40...
Страница 52: ...6 Security 6 6 May 2002 8700 A2 GB20 40...
Страница 96: ...9 Transferring Firmware and Configurations Using TFTP 9 6 May 2002 8700 A2 GB20 40...
Страница 148: ...C Connector Pin Assignments C 4 May 2002 8700 A2 GB20 40...
Страница 150: ...D Technical Specifications D 2 May 2002 8700 A2 GB20 40...
Страница 182: ...Index IN 6 May 2002 8700 A2 GB20 40...