Displaying System Information
4-13
9121-A2-GB20-00
June 1997
Message
What To Do
What It Indicates
Network LLB Test
Active
A Network Line Loopback
(LLB) test is active.
Allow the loopback to continue
or abort the test.
Press Return (
↵
) while the
loopback is selected (via the
Command column) on the
Network Physical Tests screen
( Path: main/test/network _ phy)
to activate or deactivate the
test.
Network PLB Test
Active
A Network Payload
Loopback (PLB) test is
active.
Allow the loopback to continue
or abort the test.
Press Return (
↵
) while the
loopback is selected (via the
Command column) on the
Network Physical Tests screen
( Path: main/test/network _ phy)
to activate or deactivate the
test.
Network RLB Test
Active
A Network Repeater
Loopback (RLB) test is
active.
Allow the loopback to continue
or abort the test.
Press Return (
↵
) while the
loopback is selected (via the
Command column) on the
Network Physical Tests screen
( Path: main/test/network _ phy)
to activate or deactivate the
test.
PVC Loopback,
DLCI
nnnn,
1
interface
3
A PVC Loopback is running
on the selected DLCI.
Allow the loopback to
continue.
Press Return (
↵
) while the
loopback is selected (via the
Command column) on the
interface’s Physical Tests
screen ( Path:
main/test/ [network/port-1/
port-2/BRI] _ pvc ) to activate
or deactivate the test.
Send Pattern,
DLCI
nnnn,
1
interface
3
Access unit is sending a
selected test pattern on the
specified DLCI for the
interface.
When status is Active, the
amount of time the test has
been running and the
number of errors during that
time are displayed.
2
Allow the test to continue.
Press Return (
↵
) while the
test is selected (via the
Command column) on the
interface’s PVC Tests screen
( Path: main/test/ [network/
port-1/port-2/BRI] _ pvc) to
activate or deactivate the test.
1
nnnn indicates a DCLI number of 16 through 1007.
2
A count of 99999+ means that the maximum number of errors has been exceeded.
3
interface is Network, DSX-1, Port-1, Port-2, or the basic rate interface B channel.