ACCULINK 3172 and 3174 E1 DSU/CSU
C-2
March 1999
3170-A2-GB20-30
DTE Interface Configuration
Options
Table C-1
DTE Interface Configuration Options
DTE Port: Enab
Next Enab Disab Prev
DTE Drop/Insert Port. Enables the use of the DTE Drop/Insert port.
Enab – Allows the use of the DTE Drop/Insert interface.
Disab – Prohibits the use of the DTE Drop/Insert interface.
NOTE: When this configuration option is disabled, you cannot display or configure any other DTE Interface
configuration options and TS16 is set to data. If a clock source configuration option is set to DTE, it is changed
to NET.
DTE Frame: noCRC
Next CRC4 noCRC Prev
DTE Line Framing Format. Designates the framing format for the DTE Drop/Insert interface.
CRC4 – Configures for the CRC4 framing format.
noCRC – Configures for the non-CRC4 framing format.
DTE Coding: HDB3
Next AMI HDB3 Prev
DTE Line Coding. Designates the line coding format to be used on the DTE Drop/Insert interface.
AMI – Uses the Alternate Mark Inversion coding format.
HDB3 – Uses the High Density Bipolar 3 coding format.
Extrn DLB: Disab
Next Enab Disab Prev
DTE Loopback on External Contact. Allows the initiation and termination of a DTE Loopback (DLB) by an external
contact. For more information, see the
DTE Drop/Insert Interface
section in Appendix D,
Pin Assignments.
Enab – Allows the E1 DSU/CSU to begin a DLB when the external contact is closed (if the current E1 DSU/CSU state
allows a DLB to be performed). If the E1 DSU/CSU is already performing a DLB, closing the contact will have no effect.
Opening the contact takes the E1 DSU/CSU out of DLB. The E1 DSU/CSU remains in DLB as long as the contact
remains closed.
Disab – Prevents the state of the external contact from affecting the operation of DLB.
Send Ones: Enab
Next Enab Disab Prev
Send All Ones on DTE Drop/Insert Failure. Specifies the action to take on the signal transmitted to the network when a
valid signal cannot be recovered from the DTE Drop/Insert interface (due to an LOS, OOF, or AIS condition).
Enab – Sends all ones on the DS0 channels allocated to the network interface when an LOS, AIS, or OOF condition
occurs on the DTE Drop/Insert interface.
Disab – Passes the data unchanged to the network interface channels.
Содержание 3172
Страница 1: ...ACCULINK 3172 AND 3174 E1 DSU CSU OPERATOR S GUIDE Document No 3170 A2 GB20 30 March 1999 ...
Страница 6: ...ACCULINK 3172 and 3174 E1 DSU CSU E March 1999 3170 A2 GB20 30 ...
Страница 16: ...ACCULINK 3172 and 3174 E1 DSU CSU 1 6 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 26: ...ACCULINK 3172 and 3174 E1 DSU CSU 2 10 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 64: ...ACCULINK 3172 and 3174 E1 DSU CSU 3 38 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 90: ...ACCULINK 3172 and 3174 E1 DSU CSU 4 26 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 92: ...ACCULINK 3172 and 3174 E1 DSU CSU A 2 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 138: ...ACCULINK 3172 and 3174 E1 DSU CSU D 16 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 162: ...ACCULINK 3172 and 3174 E1 DSU CSU H 2 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 172: ...ACCULINK 3172 and 3174 E1 DSU CSU Glossary 10 March 1999 3170 A2 GB20 30 This page intentionally left blank ...