B-1
3170-A2-GB20-30
March 1999
Technical Specifications
Overview
B-1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
The technical specifications for the Models 3172
and 3174 DSU/CSUs are listed in Table B-1.
Table B-1
(1 of 2)
Models 3172/3174 DSU/CSUs Technical Specifications
Specifications
Criteria
POWER REQUIREMENTS
Typical:
AC Power Module
Optional:
+24 Vdc
– 48 Vdc
– 48 Vdc Redundant
Refer to the labeling on the ac power module for input requirements
+20 Vdc to +32 Vdc, 0.50A
–38 Vdc to –60 Vdc, 0.25A
–38 Vdc to –60 Vdc, 0.25A
POWER CONSUMPTION
AND DISSIPATION
16.0 watts, 55.0 Btu per hour at 115 volts (ac power); 12.0 watts, 41 Btu per hour
at +24 and – 48 Vdc (dc power)
DTE Drop/Insert INTERFACE
Physical Interface
Framing Format
Coding Format
DB15 socket for 120 ohm twisted pair (balanced)
CRC-4, non-CRC-4
AMI, HDB3
NETWORK E1 INTERFACE
Physical Interface
Framing Format
Coding Format
Signal Recovery Capability
Typical Drive Distances:
75 ohm, coaxial cable
120 ohm, 22 AWG (0.6 mm)
120 ohm, 24 AWG (0.5 mm)
120 ohm, 26 AWG (0.4 mm)
BNC pair for 75-ohm coaxial cables (unbalanced) or
RJ48C for 120-ohm twisted pair (balanced)
CRC-4, non-CRC-4
HDB3
43 dB of cable attenuation at 1024 kHz
3.4 km
2.3 km
1.8 km
1.5 km
B
Содержание 3172
Страница 1: ...ACCULINK 3172 AND 3174 E1 DSU CSU OPERATOR S GUIDE Document No 3170 A2 GB20 30 March 1999 ...
Страница 6: ...ACCULINK 3172 and 3174 E1 DSU CSU E March 1999 3170 A2 GB20 30 ...
Страница 16: ...ACCULINK 3172 and 3174 E1 DSU CSU 1 6 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 26: ...ACCULINK 3172 and 3174 E1 DSU CSU 2 10 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 64: ...ACCULINK 3172 and 3174 E1 DSU CSU 3 38 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 90: ...ACCULINK 3172 and 3174 E1 DSU CSU 4 26 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 92: ...ACCULINK 3172 and 3174 E1 DSU CSU A 2 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 138: ...ACCULINK 3172 and 3174 E1 DSU CSU D 16 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 162: ...ACCULINK 3172 and 3174 E1 DSU CSU H 2 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 172: ...ACCULINK 3172 and 3174 E1 DSU CSU Glossary 10 March 1999 3170 A2 GB20 30 This page intentionally left blank ...