ACCULINK 3172 and 3174 E1 DSU/CSU
4-16
March 1999
3170-A2-GB20-30
Starting a Line Loopback
The Line Loopback command (LLB) loops the
received signal on the network interface back to the
network without change.
To perform a Line loopback:
"
Procedure
1. Press F2 to select Test from the top-level display
screen.
2. From the Test screen, press F2 to select Lpbk.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Loopback screen, press F2 to select
LLB.
F1
Loopback:
Abort
LLB
PLB
F2
F3
Test Started appears on Line 2. If a line loopback
is already in progress, the Already Active
message appears. If an invalid combination of
loopbacks is in progress, the error message Invld
Test Combo appears (see
Table 4-8
for valid
loopback test combinations).
Starting a Payload Loopback
The Payload Loopback command (PLB) loops the
received signal on the network interface back to the
network. The signal is looped back as close to the DTE
Drop/Insert port as possible (after it has passed through
the framing circuitry of the E1 DSU/CSU). Therefore,
framing CRCs and BPVs are corrected.
To perform a Payload loopback:
"
Procedure
1. Press F2 to select Test from the top-level menu
screen.
2. From the Test screen, press F2 to select Lpbk.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Loopback screen, press F3 to select
PLB.
F1
Loopback:
Abort
LLB
PLB
F2
F3
Test Started appears on Line 2. If a Payload
loopback is already in progress, the Already
Active message appears. If an invalid combination
of loopbacks is in progress, the error message
Invld Test Combo appears (see
Table 4-8
for
valid loopback test combinations).
Содержание 3172
Страница 1: ...ACCULINK 3172 AND 3174 E1 DSU CSU OPERATOR S GUIDE Document No 3170 A2 GB20 30 March 1999 ...
Страница 6: ...ACCULINK 3172 and 3174 E1 DSU CSU E March 1999 3170 A2 GB20 30 ...
Страница 16: ...ACCULINK 3172 and 3174 E1 DSU CSU 1 6 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 26: ...ACCULINK 3172 and 3174 E1 DSU CSU 2 10 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 64: ...ACCULINK 3172 and 3174 E1 DSU CSU 3 38 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 90: ...ACCULINK 3172 and 3174 E1 DSU CSU 4 26 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 92: ...ACCULINK 3172 and 3174 E1 DSU CSU A 2 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 138: ...ACCULINK 3172 and 3174 E1 DSU CSU D 16 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 162: ...ACCULINK 3172 and 3174 E1 DSU CSU H 2 March 1999 3170 A2 GB20 30 This page intentionally left blank ...
Страница 172: ...ACCULINK 3172 and 3174 E1 DSU CSU Glossary 10 March 1999 3170 A2 GB20 30 This page intentionally left blank ...